Technology

Specs, certifications, protocols.

Everything a procurement team asks for, on one page, as real tables.

  • OCPP 2.0.1controlConfirm
  • ISO 15118Plug & ChargeConfirm
  • IEC TS 63379MCS-readyConfirm

MegaWatts mobile charging blocks are specified at 350 kW, 700 kW and 1 MW+ with on-board storage, CCS1 and NACS dispensers and MCS readiness under IEC TS 63379. Intended certifications are UL 1973, UL 9540A and UL 2202; protocols are OCPP 2.0.1 and ISO 15118; every dispenser reports to a 24/7 telemetry dashboard.

Block specifications

By block size.

MegaWatts block specifications
Spec350 kW block700 kW block1 MW+ block
Continuous output350 kWConfirm700 kWConfirm1,000 kWConfirm
Peak output400 kWConfirm800 kWConfirm1,200 kWConfirm
On-board storage700 kWhConfirm1,400 kWhConfirm2,000 kWhConfirm
Dispensers per block2Confirm4Confirm6Confirm
Per-dispenser power150–350 kWConfirm150–350 kWConfirm150–400 kW (1 MW+ via MCS)Confirm
ConnectorsCCS1 · NACSCCS1 · NACSCCS1 · NACS · MCS-ready
MCS readinessUpgrade pathConfirmMCS-readyConfirmMCS (IEC TS 63379) dispenser optionConfirm
Footprint20 ft × 8.5 ftConfirm40 ft × 8.5 ftConfirm53 ft × 8.5 ftConfirm
Weight≈ 22,000 lbConfirm≈ 44,000 lbConfirm≈ 60,000 lbConfirm
IP ratingIP54 (NEMA 3R)ConfirmIP54 (NEMA 3R)ConfirmIP54 (NEMA 3R)Confirm
CertificationsUL 1973 · UL 9540A · UL 2202ConfirmUL 1973 · UL 9540A · UL 2202ConfirmUL 1973 · UL 9540A · UL 2202Confirm
Energy sourceBattery + grid-tied or low-emission generationConfirmBattery + grid-tied or low-emission generationConfirmBattery + grid-tied or low-emission generationConfirm
Runtime at rated load2 hr at 350 kWConfirm2 hr at 700 kWConfirm2 hr at 1 MWConfirm

Certifications and standards

What each standard covers.

Standards and certifications applicable to MegaWatts blocks
StandardCoversStatus
UL 1973Batteries for stationary and motive auxiliary powerFounder to confirmConfirm
UL 9540AThermal runaway fire propagation test methodFounder to confirmConfirm
UL 2202EV charging system equipmentFounder to confirmConfirm
OCPP 2.0.1Open charge point protocol for back-office controlFounder to confirmConfirm
ISO 15118Plug & Charge and smart-charging communicationFounder to confirmConfirm
MCS / IEC TS 63379Megawatt Charging System readinessFounder to confirmConfirm
CARB / EPAEmissions compliance for on-site generationFounder to confirmConfirm

IEC TS 63379 (MCS) was published in February 2026. EV Infrastructure News, MCS guide · 2026

Three dual-port DC fast chargers being commissioned in a workshop with a laptop on a bench connected to the chargers
Dispenser commissioning and OCPP setup before dispatch

Commissioning

Every dispenser is bench-tested before it ships.

OCPP 2.0.1 link, ISO 15118 handshake, emergency-stop and thermal checks run on the bench, then again on the pad. Session data flows to the NOC from the first charge.

Telemetry

What the dashboard shows.

  • Dispenser status

    Available, charging, faulted, reserved. Per port, live.

  • Sessions

    Start, end, kWh, peak kW, SOC in and out, vehicle ID.

  • Energy

    kWh delivered per day, per vehicle, per block; storage state.

  • Faults and MTTR

    Every fault with response and resolution timestamps against the SLA.

  • Exports

    CSV daily, REST API, OCPP 2.0.1 to your CSMS.

  • Site view

    Block state of charge, recharge source, generator runtime log.

Spec sheet

One PDF for the RFP.

MegaWatts power blocks — specification sheetConfirm

Spec table, certification list, protocol support, footprint drawings. Published once the founder confirms the block catalog.

Request the spec sheet

FAQ

Technical questions.

Which protocols do the blocks speak?

OCPP 2.0.1 for charger control and telemetry to your CSMS or fleet platform, ISO 15118 for Plug & Charge and smart-charging, and a REST session feed from the NOC. Founder to confirm certification status.

What does MCS-ready mean in practice?

The 1 MW+ block's DC bus, cooling and controller are designed for a Megawatt Charging System dispenser under IEC TS 63379. The MCS dispenser is an option with a founder-set availability date.

How is safety certified?

The intended certification set is UL 1973 for the battery, UL 9540A for thermal runaway testing, and UL 2202 for the charging system. Each is marked for founder confirmation until certificates are published here.

Can we see live data?

Yes. The telemetry dashboard shows per-dispenser status, sessions, kWh, SOC delivered and faults, with exports and an API.

Is there a spec sheet we can attach to an RFP?

Yes, on this page. It contains the spec table, certification list and protocol support in one PDF.

Start here

Get a Site Power Plan in 48 hours.

kW, kWh, blocks, layout and days-to-live for your site. Free, whether or not you buy. Three fields to start.